All Categories > Medium Voltage Power Cable 
 

Medium Voltage Power Cable

Click on a Product to view details.

Request Information
25030

EPR-CPE (2400V Unshielded) Type MV90 Power Cable - Wet and Dry Location

 (13)
Application:
  • Where NEC juisdiction applies; as 2,400-volt nonshielded power cable, Type MV-90, for use at conductor temperatures not exceeding 90ºC in wet or dry locations. Cables meet requirements of Article 310.6 of the National Electrical Code.
  • For use in aerial, conduit, open tray and underground duct installations.
  • Excellent heat and moisture resistance.
  • Low moisture absorption.
  • High dielectric strength.
  • Low dielectric loss.
  • Chemical and sunlight resistant.
  • Meets cold bend test at -35ºC.

  • 25051

    EPR-PVC (5000/ 8000V Shielded) Type MV-105 Power Cable- Sunlight Resistant, CT USE

     (13)
    Medium voltage MV-105 power cable for use in main feeder, distribution and branch circuits in industrial, commercial and electric utility installations. Cables may be used in wet or dry locations in circuits not exceeding 5000 volts 133% insulation level or 8000 volts 100% insulation level, at conductor temperatures not exceeding 105°C for normal, 140°C for emergency overload and 250°C for short-circuit conditions. Suitable for installation in conduit, tray, trough, ducts, aerial and direct burial applications.

    25130

    EPR-PVC (15000V Shielded, Grounded) Type MV105 Power Cable - 100% Insulation Level

     (11)
    As medium voltage MV-105 power cable for use in main feeder, distribution and branch circuits in industrial, commercial and electric utility installations. Cables may be used in wet or dry locations in circuits not exceeding 15000 volts 100% insulation level, at conductor temperatures not exceeding 105°C for normal, 140°C for emergency overload and 250°C for short-circuit conditions.Cables may be installed in conduit, duct or aerially when properly supported by a messenger.

    25130

    EPR-PVC (15000V Shielded, Ungrounded) Type MV105 Power Cable - 133% Insulation Level

     (11)
    As medium voltage MV-105 power cable for use in main feeder, distribution and branch circuits in industrial, commercial and electric utility installations. Cables may be used in wet or dry locations in circuits not exceeding 15000 volts 100% insulation level, at conductor temperatures not exceeding 105°C for normal, 140°C for emergency overload and 250°C for short-circuit conditions.Cables may be installed in conduit, duct or aerially when properly supported by a messenger.

    25310

    EPR-PVC (35000V Shielded, Grounded) Type MV-90- Power Cable - 100% Insulation .005 Copper Tape Shield PVC Jacket

     (18)
    Cable is suitable for use in dry or wet locations at conductor temperatures not exceeding 90°C normal use, 130°C emergency overload, 250°C short circuit. All sizes may be installed in conduit, duct, or directly buried.

    Medium Voltage Power Cables

    EPR Power Cable - 2,400V (Unshielded) - 3 Conductor

     (12)
    Three Conductor, EPR Insulation, PVC Jacket, 2400 Volt, Unshielded, MV 105

    Medium Power 5kV, 8kV Shielded Cables

    EPR Power Cable- 5KV / 8KV (Shielded)- 3 Conductor

     (11)
    Three Conductor, EPR Insulation/Copper Tape Shield With Overall PVC Jacket, Shielded 5kV And 8kV, UL Type MV-105, 133%/100% Ins. Levels, 115 Mil Insulation

    Medium Power 15kV Shielded Cables

    EPR Power Cable - 15,000V (Shielded) - 3 Conductor

     (9)
    Three Conductor, EPR Insulation/Copper Tape Shield With Overall PVC Jacket. Shielded, 15kV, UL Type MV-105, 133%/100% Ins. Levels, 220 Mil Insulation

    Airport Lighting Power Cable

    Airport Lighting CableType C- FAA L824 Crosslinked Polyethylene Unshielded- 5000 V -

     (3)
    Application
  • Electrical cables for airport lighting circuits.
  • Use in wet and dry locations.
  • 90°C use for continuous operation.
  • 130°C use for emergency overload.
  • 250°C use for short circuit conditions.

  • 25400

    EPR CPE Unishield- Shielded Power Cable Type MV-90, 5000 V 133% or 8000 V 100% 90°C

     (30)
    Applications
  • Commercial, industrial and utility projects such as pulp and paper mills, petrochemical plants, steel mills, textile mills, water and sewage treatment facilities, environmental protection systems, railroads, mines and both fossil fuel and nuclear powered generating stations.

  • Medium Voltage Power Cable NEW

    Low Smoke, Zero Halogen (LSZH) 5KV/8KV Shielded Cables

     (13)
    EPR/Copper Tape Shield/LSZH, Medium-Voltage Power, Shielded 5kV and 8kV, UL Type MV-105, 133%/100% ins. Levels, 115 Mils

    Dimensions and weights are nominal; subject to industry tolerances.


    Low Smoke, Zero Halogen (LSZH) 15kV Shielded Cables

    Low Smoke, Zero Halogen (LSZH) 15kV Shielded Cables

     (11)
    EPR/Copper Tape Shield/LSZH, Medium-Voltage Power, Shielded 15kV, UL Type MV-105, 133% ins. Level, 220 Mils

    Dimensions and weights are nominal; subject to industry tolerances.


    Low Smoke, Zero Halogen (LSZH) 3 Conductor, 5kV / 8kV Shielded Cables

    Low Smoke, Zero Halogen (LSZH) 3 Conductor, 5kV / 8kV Shielded Cables

     (11)
    EPR/Copper Tape Shield with Overall LSZH Jacket, Medium-Voltage Power, Shielded 5kV and 8kV, UL Type MV-105, 133%/100% ins. Levels, 115 Mils, Three Conductor

    Dimensions and weights are nominal; subject to industry tolerances.


    Low Smoke, Zero Halogen (LSZH) 3 Conductor, 15kV Shielded Cables

    Low Smoke, Zero Halogen (LSZH) 3 Conductor, 15kV Shielded Cables

     (9)
    EPR/Copper Tape Shield with Overall LSZH Jacket Medium-Voltage Power, Shielded 15kV, UL Type MV-105, 133% Ins. Level, 220 Mils, Three Conductor

    Dimensions and weights are nominal; subject to industry tolerances.


    Preassembled Self-Supporting Medium Voltage Power Cable

    Preassembled Self-Supporting Aerial Cable

     (39)
    Class B strand, bare annealed copper, insulated with heat and moisture resistant XHHW . The conductors shall be cabled in a left hand lay and a messenger of 30% E.H.S. copperclad steel shall be laid parallel and banded with a rounded edge flat bare copper binding strap.

    13500

    Primary Underground Distribution Cable- 15kV Type (URD)- Aluminum XLP or TR-XLP Insulation (Full Neutral)

     (25)
    For use on Single Phase Underground Distribution Systems with solidly grounded neutral, suitable for direct burial or installation in ducts.

    13470

    Primary Underground Distribution Cable- 15kV Type (URD) Copper XLP or TR-XLP Insulation (Full Neutral)

     (18)
    For use on Single Phase Underground Distribution Systems with solidly grounded neutral, suitable for direct burial or installation in ducts.

    13600

    XLP Power Cable- 15,000V (Shielded, Grounded)- 3 Conductor MV-90 with Grounding Conductor 100% Insulation (Grounded Neutral)

     (18)
    Phase identified, (Color coded tape (Black, Red, Blue) applied under the metallic shielding tape) and cabled together with fillers and bare copper ground conductor.

    13440

    XLP Power Cable- 15,000V (Shielded, Grounded) Type MV-90- 100% Insulation Level

     (11)
    As medium voltage MV-90 power cable for use in main feeder, distribution and branch circuits in industrial, commercial and electric utility installations. Cables may be used in wet or dry locations in circuits not exceeding 15000 volts, 100% insulation level, at conductor temperatures not exceeding 90°C for normal, 130°C for emergency overload and 250°C for short-circuit conditions. Suitable for installation in conduit, trough, ducts, aerial and direct burial applications.

    Medium Voltage Power Cable

    XLP Power Cable- 5,000V (Shielded)- 3 Conductor with Grounding Conductor 133% Insulation

     (13)
    Unshielded: Class B stranded copper, extruded conductor shield, insulated with heat and moisture resistant crosslinked polyethylene (type XLP)

    Medium Voltage Power Cable

    XLP Power Cable- 5,000V (Unshielded)- 3 Conductor with Grounding Conductor 100% Insulation

     (13)
    Unshielded: Class B stranded copper, extruded conductor shield, insulated with heat and moisture resistant crosslinked polyethylene (type XLP).

    Medium Voltage Power Cable

    XLP Power Cable- 5,000V (Unshielded) Type MV-90

     (14)
    Where NEC jurisdiction applies; as 5,000 volt non-shielded power cable, Type MV-90 Dry, for use at conductor temperatures not exceeding 90°C in dry locations. Cables meet requirements of Article 310-6 of the NEC.

    13420

    XLP Power Cable 5000 V (Shielded) Type MV-90- Wet and Dry Locations

     (14)
    5000 volt shielded power cable, Type MV-90, for general purpose applications in accordance with the NEC at conductor temperatures not exceeding 90°C in wet or dry locations for normal operation, 130°C for emergency overload, and 250°C for short circuit conditions. Suitable for installation in conduit, trough, ducts, aerial and direct burial applications.

    13459

    XLP Power Cable-15,000V (Shielded, Ungrounded) Type MV-90- 133% Insulation Level

     (11)
    As medium voltage MV-90 power cable for use in main feeder, distribution and branch circuits in industrial, commercial and electric utility installations. Cables may be used in wet or dry locations in circuits not exceeding 15000 volts, 100% insulation level, at conductor temperatures not exceeding 90°C for normal, 130°C for emergency overload and 250°C for short-circuit conditions. Suitable for installation in conduit, trough, ducts, aerial and direct burial applications.

    Medium Voltage Power Cable

    EPR-PVC (2400V Unshielded)Type MV90 Power Cable- Wet and Dry Location

     (14)
    Where NEC jurisdiction applies; as 2,400- volt non-shielded power cable, Type MV-90, for use at conductor temperatures not exceeding 90°C in wet or dry locations. Cables meet requirements of Article 310-6 of the NEC.

    25101

    EPR-PVC (15000V Grounded, Shielded) Type MV90 Power Cable- 100 % Insulation Level

     (11)
    As medium voltage MV-90 power cable for use in main feeder, distribution and branch circuits in industrial, commercial and electric utility installation. Cables may be used in wet or dry locations in circuits not exceeding 15000 volts 100% insulation level, at conductor temperatures not exceeding 90°C for normal, 130°C for emergency overload and 250°C for short circuit conditions. Suitable for installation in conduit, tray, trough, ducts, aerial and direct burial applications.